SE-4SO2-2000-F (SO₂)

Electrochemical SO₂ Sensor (0–2000 ppm)

The SE-4SO2-2000-F is an electrochemical sensor designed for accurate detection of sulfur dioxide (SO₂) gas within the 0 to 2000 ppm range. It is suitable for both fixed and portable gas detection devices, offering linear output and high resolution below 0.5 ppm. The sensor demonstrates excellent selectivity, showing no response to major interfering gases such as CO, Cl₂, CO₂, and NH₃. Additionally, it features a built-in filter with a capacity of 1000 ppm·hours that eliminates interference from H₂S, enabling precise measurements even in mixed-gas environments. The sensor operates reliably from -20℃ to +50℃ and provides an operating life of more than 24 months in air.

KEY FEATURES
    • Measurement Range: 0–2000 ppm
    • Sensitivity: 60 ± 20 nA / ppm
    • Response Time: T90 < 60 sec
    • Resolution: < 0.5 ppm
    • Operating Life: ≥ 24 months in air
    • Operating Temperature Range: -20℃ to +50℃
    • Low Cross-Sensitivity To: CO, Cl₂, CO₂, NH₃, H₂S, etc.
Product Inquiry

SE-4SO2-2000-F

Electrochemical SO₂ Sensor (0–2000 ppm)

Product Description

The SE-4SO2-2000-F is an electrochemical sensor designed for accurate detection of sulfur dioxide (SO₂) gas within the 0 to 2000 ppm range. It is suitable for both fixed and portable gas detection devices, offering linear output and high resolution below 0.5 ppm. The sensor provides excellent selectivity with no response to major interfering gases such as CO, Cl₂, CO₂, and NH₃.

Additionally, it features a built-in filter with a capacity of 1000 ppm·hours that eliminates interference from H₂S, enabling precise measurements even in mixed-gas environments. The sensor operates reliably from -20℃ to +50℃ and provides an operating life of more than 24 months in air.


Key Features

- Measurement range: 0–2000 ppm
- Sensitivity: 60 ± 20 nA / ppm
- Response time: T90 < 60 sec
- Resolution: < 0.5 ppm
- Operating life: ≥ 24 months in air
- Operating temperature range: -20℃ to +50℃
- Low cross-sensitivity to: CO, Cl₂, CO₂, NH₃, H₂S, etc.


Product Specifications
Performance Characteristics
Output Signal60 ± 20 nA / ppm
Typical Baseline Range (pure air, @ 20℃)≤ ±2 ppm SO₂ equivalent
Response Time (T90)< 60 seconds
Filter1000 ppm·hours H₂S filter capacity
Measurement Range0–2000 ppm
Maximum Overload5000 ppm
LinearityLinear
Repeatability< ±5% of signal
Recommended Load Resistor10 ohms
Resolution (Electronics Dependent)< 0.5 ppm typical
Bias VoltageNot required
Environmental
Temperature Range Continuous-20℃ to +50℃
Pressure Range800 to 1200 mbar
Operating Humidity Range15% to 90% RH
Lifetime
Long Term Output Drift< 10% per annum
Recommended Storage Temp0℃ to 20℃
Expected Operating Life> 24 months in air
Standard Warranty24 months from date of dispatch
Intrinsic Safety Data
Maximum at 5000 ppm300 µA
Maximum o/c Voltage< 1.0 V
Maximum s/c Current< 0.1 A
Sensor Specifications